Closes #19.

  • Write feet and inches as length conversion units, and write sweep angles in the declared plane angle unit while keeping radians in the API. Read declared unit factors and keep positive small angles representable.
  • Add an explicit read/migration option for old IfcIO exports that mislabeled radian sweeps as degrees. Do not guess from the numeric angle.
  • Normalize length quantities to the model length unit and give metre-based cost quantities their explicit unit. The info command labels storey elevations with the model unit. Area and volume quantity handling is unchanged.

Release suite: 246 passed, 2 skipped, 0 failed. DocFX: 0 warnings, 0 errors. IfcOpenShell independently checked the unit factors and sweep angles; CLI migration was exercised on a synthetic mislabeled file and the repaired angle was checked independently.